BUILDING GENERAL:
- DESIGN LOAD [Table R301.2(1)]
- Floor Live Load _______________psf
- Roof Live Load _______________psf
- Ground Snow Load ____________psf
- Basic Wind Speed _____________mph (3-second gust)
- Wind Exposure Category ______
- PLAT PLAN:
- Less than or equal to 3’ from property line-1 hour fire-resistance rating; no openings permitted
- Less than or equal to 5’ but greater than 3’ from property line-1 hour fire-resistance rating; 25% of wall area permitted to be unprotected openings.
- Aircraft noise zone
- GLAZING (R308)
- Safety glazing locations
- Skylight and sloped glazing
- GARAGES AND CARPORTS (R309)
- Garage does not open into a sleeping area
- Door between garage and residence-1 3/8” solid core or 20-minute fire-resistance rated
- Garage floor - noncombustible; slopes to main door
- ½” gypsum board on garage side between residence and garage
- 5/8” gypsum board on ceiling and loadbearing walls of garage with habitable space above
- EGRESS (R310 THRU R316)
- Exit door (minimum 3’- 0” X 6’- 8”)
- Exit hallway (minimum 3’- 0” width)
- Stairways
- Minimum width (3’- 0”)
- 8 1/4” maximum riser; 9” minimum tread width
- Headroom (minimum 6’- 8” from nosing)
- Landing (minimum 36” in the direction of travel)
- Winder, spiral, circular
- Illumination
- Under stair protection (1/2” gypsum board on all exposed framing)
- Handrail (34” – 38” high; 4” picket spacing)
- Guardrail (porches, balconies, open side of stairs or raised floors >30”) 34” – 36” high, 4” picket spacing
- SMOKE ALARMS (R317)
- Location and power source
- DWELLING UNIT SEPARATION (R321)
- Two family dwelling (1-hour fire-resistance rating)
- Townhouse (2-hour fire-resistance rating)
- Continuity
- Structural independence
- Penetration protection
- MOISTURE VAPOR RETARDERS (R322)
- FLOOD RESISTANT CONSTRUCTION (R 327.1)
- Hazard area (A zone or V zone)
- Elevation certification
- Electrical/mechanical equipment location
FOUNDATION:
- CONCRETE COMPRESSIVE STRENGTH (R403.2)
- FOOTING (R403)
- Soil type and bearing
- Minimum width (Table R403.1)
- Edge thickness (6” minimum; projection 2” minimum but not greater than footing thickness)
- Depth below grade
- Foundation anchorage (R403.1.6)
- FOUNDATION WALL (R404 THRU R406)
- Masonry wall (maximum height; minimum thickness; reinforcing size and spacing)
- Sill plate size (anchor bolt ½” diameter, 7” embedment, 6’- 0” o.c. maximum, 12” from corners)
- ICF (R404.4)
- COLUMNS (R407)
- Decay and corrosion protection
- Structural requirements
- Anchorage
- Wood columns (minimum 4” square; R407.3)
a. Steel columns (minimum 3” diameter, standard weight; R407.3)
- UNDERFLOOR SPACE (R408)
- Ventilation (1 square foot / 150 square feet of space; one opening 3 feet from each corner)
- Access (minimum 18” x 24” or Mechanical requirement)
- Flood resistance (R408.6)
FLOORS:
- WOOD JOIST AND GIRDERS (R 502)
- Live load (sleeping areas-30psf; nonsleeping areas-40psf)
- Girder and header span [exterior bearing walls-Table R502.5.(1); interior bearing walls-Table R502.5.(2)]
- Joists under bearing partitions
- Bearing (11/2” minimum on wood or metal; 3” on masonry or concrete); joist lapped 3”
- Pre-engineered floor system (registered design professional)
- Draftstopping
- Sheathing
- Insulation (R-19 minimum)
- Slab-on-grade
- Thickness (3 1/2” minimum; concrete strength)
- Subgrade (8” maximum earth fill; 24” sand and gravel)
- Vapor retarder (6 mil minimum between slab and fill)
- Insulation (R-4.5; 24” total length)
WALLS:
- WINDOWS IN WIND BORNE DEBRIS REGIONS (R301.2.1.2)
- WOOD CONSTRUCTION (R602)
- Stud spacing (2-stories or less- 2X4 @ 16” o.c.; over 2-stories- 2X6 @ 16” o.c. or 2X4 @ 12” o.c.)
- Interior bearing walls
- Headers
- Fireblocking
- Braced walls (R602.10.1 & 602.10.4)
- STEEL WALL FRAMING (R603)
- SHEATHING (R604 & R605)
- MASONRY CONSTRUCTION (R606 THRU R610)
- Design
- Grouted masonry
- Glass unit masonry
- INSULATING CONCRETE FORM WALL CONSTRUCTION (R611)
- Design
- Type of ICF
- Construction requirements
- WINDOWS AND DOORS (R613)
- Performance (fire rating; STC, U-value)
- INSULATION
ROOF-CEILING:
- ROOF FRAMING (R802)
- Rafter tie (4’- 0” o.c.)
- Purlins (2X4 @ 4’- 0” o.c.)
- Bearing (1 ½” on wood or metal; 3” on masonry or concrete)
- Pre-engineered elements (registered design professional)
- Hurricane ties (each end of each rafter or truss)
- CEILING JOISTS [Tables R802.4(1), R802.4(2)]
- Design loads (without storage- 10psf; with storage- 20psf)
- Span, spacing and size
- RAFTERS [Tables R802.5.1(1) thru R802.5.1(8)]
- Design loads (ground snow- 15psf; live load 20psf with or without ceiling attacheds)
- Span, spacing and size
- SHEATHING (R803.2)
- Thickness
- FRTW (reduced spans)
- STEEL FRAMING (R804)
- ROOF VENTILATION (R806)
- Minimum area (1 square foot / 150 square feet of attic area or 1 square foot / 300 square feet of roof area with high and low vents)
- ACCESS (R807)
- INSULATION (R906)
- Minimum R-value (R-23 at ceiling joists; R-30 for cathedral ceiling)
- WEATHER PROTECTION (R903)
- ROOF COVERINGS (R905)
CHIMNEYS AND FIREPLACES:
- Masonry fireplace (R1003)
- Factory built fireplace (R1004)
ENERGY CONSERVATION:
- Building envelop (N1102)
- Mechanical systems (N1103)
- Service water heating (N1104)
|