BUILDING GENERAL:

  • DESIGN LOAD [Table R301.2(1)]
    • Floor Live Load _______________psf
    • Roof Live Load _______________psf
    • Ground Snow Load ____________psf
    • Basic Wind Speed _____________mph (3-second gust)
    • Wind Exposure Category ______
  • PLAT PLAN:
    • Less than or equal to 3’ from property line-1 hour fire-resistance rating; no openings permitted
    • Less than or equal to 5’ but greater than 3’ from property line-1 hour fire-resistance rating; 25% of wall area permitted to be unprotected openings.
    • Aircraft noise zone
  • GLAZING (R308)
    • Safety glazing locations
    • Skylight and sloped glazing
  • GARAGES AND CARPORTS (R309)
    • Garage does not open into a sleeping area
    • Door between garage and residence-1 3/8” solid core or 20-minute fire-resistance rated
    • Garage floor - noncombustible; slopes to main door
    • ½” gypsum board on garage side between residence and garage
    • 5/8” gypsum board on ceiling and loadbearing walls of garage with habitable space above
  • EGRESS (R310 THRU R316)
    • Exit door (minimum 3’- 0” X 6’- 8”)
    • Exit hallway (minimum 3’- 0” width)
    • Stairways
      • Minimum width (3’- 0”)
      • 8 1/4” maximum riser; 9” minimum tread width
      • Headroom (minimum 6’- 8” from nosing)
      • Landing (minimum 36” in the direction of travel)
      • Winder, spiral, circular
      • Illumination
      • Under stair protection (1/2” gypsum board on all exposed framing)
      • Handrail (34” – 38” high; 4” picket spacing)
      • Guardrail (porches, balconies, open side of stairs or raised floors >30”) 34” – 36” high, 4” picket spacing
  • SMOKE ALARMS (R317)
    • Location and power source
  • DWELLING UNIT SEPARATION (R321)
    • Two family dwelling (1-hour fire-resistance rating)
    • Townhouse (2-hour fire-resistance rating)
      • Continuity
      • Structural independence
      • Penetration protection
  • MOISTURE VAPOR RETARDERS (R322)
  • FLOOD RESISTANT CONSTRUCTION (R 327.1)
    • Hazard area (A zone or V zone)
    • Elevation certification
    • Electrical/mechanical equipment location

FOUNDATION:

  • CONCRETE COMPRESSIVE STRENGTH (R403.2)
  • FOOTING (R403)
    • Soil type and bearing
    • Minimum width (Table R403.1)
    • Edge thickness (6” minimum; projection 2” minimum but not greater than footing thickness)
    • Depth below grade
    • Foundation anchorage (R403.1.6)
  • FOUNDATION WALL (R404 THRU R406)
    • Masonry wall (maximum height; minimum thickness; reinforcing size and spacing)
    • Sill plate size (anchor bolt ½” diameter, 7” embedment, 6’- 0” o.c. maximum, 12” from corners)
    • ICF (R404.4)
  • COLUMNS (R407)
    • Decay and corrosion protection
    • Structural requirements
    • Anchorage
    • Wood columns (minimum 4” square; R407.3)

    • a. Steel columns (minimum 3” diameter, standard weight; R407.3)
  • UNDERFLOOR SPACE (R408)
    • Ventilation (1 square foot / 150 square feet of space; one opening 3 feet from each corner)
    • Access (minimum 18” x 24” or Mechanical requirement)
    • Flood resistance (R408.6)

FLOORS:

  • WOOD JOIST AND GIRDERS (R 502)
    • Live load (sleeping areas-30psf; nonsleeping areas-40psf)
    • Girder and header span [exterior bearing walls-Table R502.5.(1); interior bearing walls-Table R502.5.(2)]
    • Joists under bearing partitions
    • Bearing (11/2” minimum on wood or metal; 3” on masonry or concrete); joist lapped 3”
    • Pre-engineered floor system (registered design professional)
    • Draftstopping
    • Sheathing
    • Insulation (R-19 minimum)
    • Slab-on-grade
      • Thickness (3 1/2” minimum; concrete strength)
      • Subgrade (8” maximum earth fill; 24” sand and gravel)
      • Vapor retarder (6 mil minimum between slab and fill)
      • Insulation (R-4.5; 24” total length)

WALLS:

  • WINDOWS IN WIND BORNE DEBRIS REGIONS (R301.2.1.2)
  • WOOD CONSTRUCTION (R602)
    • Stud spacing (2-stories or less- 2X4 @ 16” o.c.; over 2-stories- 2X6 @ 16” o.c. or 2X4 @ 12” o.c.)
    • Interior bearing walls
    • Headers
    • Fireblocking
    • Braced walls (R602.10.1 & 602.10.4)
  • STEEL WALL FRAMING (R603)
  • SHEATHING (R604 & R605)
  • MASONRY CONSTRUCTION (R606 THRU R610)
    • Design
    • Grouted masonry
    • Glass unit masonry
  • INSULATING CONCRETE FORM WALL CONSTRUCTION (R611)
    • Design
    • Type of ICF
    • Construction requirements
  • WINDOWS AND DOORS (R613)
    • Performance (fire rating; STC, U-value)
  • INSULATION
    • Minimum R-value (R-13)

ROOF-CEILING:

  • ROOF FRAMING (R802)
    • Rafter tie (4’- 0” o.c.)
    • Purlins (2X4 @ 4’- 0” o.c.)
    • Bearing (1 ½” on wood or metal; 3” on masonry or concrete)
    • Pre-engineered elements (registered design professional)
    • Hurricane ties (each end of each rafter or truss)
  • CEILING JOISTS [Tables R802.4(1), R802.4(2)]
    • Design loads (without storage- 10psf; with storage- 20psf)
    • Span, spacing and size
  • RAFTERS [Tables R802.5.1(1) thru R802.5.1(8)]
    • Design loads (ground snow- 15psf; live load 20psf with or without ceiling attacheds)
    • Span, spacing and size
  • SHEATHING (R803.2)
    • Thickness
    • FRTW (reduced spans)
  • STEEL FRAMING (R804)
  • ROOF VENTILATION (R806)
    • Minimum area (1 square foot / 150 square feet of attic area or 1 square foot / 300 square feet of roof area with high and low vents)
  • ACCESS (R807)
    • Minimum size (22” X 30”)
  • INSULATION (R906)
    • Minimum R-value (R-23 at ceiling joists; R-30 for cathedral ceiling)
  • WEATHER PROTECTION (R903)
    • Flashing
    • Roof drainage
  • ROOF COVERINGS (R905)

CHIMNEYS AND FIREPLACES:

  • Masonry fireplace (R1003)
  • Factory built fireplace (R1004)

ENERGY CONSERVATION:

  • Building envelop (N1102)
  • Mechanical systems (N1103)
  • Service water heating (N1104)